This page shows what the city's open data records for one address: the zoning and what it means, the neighbourhood, every building permit on file and, where the city publishes it, the assessed value. It also shows the property on the city's aerial photo or a drawn plan, a 2021 Census profile of the small area around it, and recent permits nearby. Free, no account. Owner names and sold prices are never shown; the assessed value is the city's estimate for property tax, not a sale price.
How to use it
- Read the top lines for the summary: zoning, neighbourhood, number of permits and assessed value.
- Use + and − on the plan to zoom in and out.
- Scroll to Permit history for every permit on the lot: what was done, when, by which company, the value and the status.
- Click a nearby permit to open its address, or This week's permit digest → for the whole city.
- Something looks wrong? Use the Tell us link at the bottom and we'll check it against the city's records.
425 Carrall St, Vancouver
An address in Downtown, Vancouver, zoned HA-2 (Historical Area). 5 building permits are on file, most recently “Mezzanine level - unit #90 Interior alterations to combine units #90 & #80 (retain #90) a…” (issued 12 January 2024). The City's 2026 assessed value is $24,683,000.
Neighbourhood profile
From the 2021 Census, for the small area around this address that Statistics Canada calls a dissemination area (59153583, 1,001 people). Statistics Canada draws these areas; they are not the City's neighbourhoods.
Permit history
-
2024-01-12
Mezzanine level - unit #90 Interior alterations to combine units #90 & #80 (retain #90) and provide improvements to for a new office tenant on the mezzanine level (full floor) of this existing commercial building on this site. Scope of work: remove and construct new partitions, doors, millwork, finishes for new layout. Electrical & sprinklers to suit. REVISION #1 - Aug 14/24 mk - changes to partition layout. · $200,000
no contractor listed Issued -
2021-05-21
#600 - 6th floor Interior alterations to relocate partition walls for new office tenant on the 6th floor (#600) and exterior alterations this existing Municipally designated Heritage A commercial building to create a secondary exit at the roof level of by adding a walkway and handrails plus a new rooftop deck. Scope of work: remove/construct partition walls and doors for 2 washrooms, lounge, offices and meeting room, new finishes, lighting, ceiling work, electrical and plumbing work. Exterior alteration to add new walkway and handrail. OK for field review per City staff: Field Review Rejected. Application will be reviewed by Building Review Branch ** Note: · $200,000
no contractor listed Issued -
2019-12-16
Elevator Upgrade, Upgrade fire alarm system for elevator modernization for two existing elevators in this existing General Office (Group D) Heritage A building as per bulletin 2018-004 BU/EL and for CSA-B44-07 upgrade. Scope of Work: - Existing conventional FA system to be upgraded to addressable single-stage. - New addressable smoke detector in elevator lobbies, machine room and top of shaft. - Lighting will be replaced with new LED Luminaries at elevator machine room and shaft - New condensing unit at exiting fenced area on ground floor and AC cooling unit in machine room Building Review Branch Notes: - The building is a Heritage A building. If there are any exterior components to the scope of work, it should be further reviewed by Heritage Planner, who would then issue the Heritage Alteration Permit (HAP). · $551,154
Action Electric Ltd Issued -
2019-07-12
#200-2nd floor (full floor tenant) Interior alterations to provide improvements for this existing office tenant at this existing office unit #200 on the second floor of this Municipally Designated Heritage 'A' commercial building on this site. Scope of work: demolish partition walls, remove doors, relocate glazing, remove shelving/millwork, acoustic panel, lights, bulkhead framing and finishes, construct new partition walls, glazing, doors, relocate cabinets, power and lighting, finishes, HVAC, electrical work to connect existing unoccupied office space with the existing tenant's office space. TENANT: Earls Restaurant Head Office OK for field review per City staff · $250,000
no contractor listed Issued -
2017-01-30
(#390) Interior alterations to provide improvements for a new office tenant in this existing office unit #390 on the 3rd floor of this existing Municipally Designated Heritage 'A' commercial building. Scope of work includes: 1) to install a stand for a mechanical unit on the roof, as per the attached drawings. The alterations described under item no. 1 above, authorized by the Development-Building Permit Number DB-2016-04031, including conditions and plans forming parts thereof, are approved under the Heritage By-law and the Development-Building Permit also constitutes a Heritage Alteration Permit. OK for DB per City staff. OK for Field Review per City staff. Schedules submitted: A/B (Arch) by Kirsten Reite, [contact removed] · $382,000
no contractor listed Issued
The City of Vancouver publishes permits when they are issued and does not show whether the work was completed, so every Vancouver permit shows as Issued with its issue date.
Email alerts and sign-up aren't available yet. Everything on these pages is free to use without an account. Questions: [email protected]
Recent permits in Downtown
To construct a 9-storey (8 storey Z&D) building containing 94 Residential Rental (Seniors Supportive Dwelling) and amenity space serving occupant of the building. Scope of work also includes façade retention, rehabilitation and restoration of the Hartney Chambers Vancouver Heritage Building (demo and retention applied under DB-2026-00299) - 1st storey includes loading/vehicle parking, storage, service room, generator & electrical room, heat treatment room - 2nd storey includes main entrance, common dining, amenity and kitchen, UTR and residential suites, - 3-9 storey includes residential units, shower room, service room. 9th storey also includes amenity room. SHORT Project · ITC Projects Inc2026-10-30
Interior alteration to convert an existing shell CRU into a Neighbourhood Public House in this 10-storey hotel building. - Refer to BP-2021-00364 for the base building. Notes: 1. This permit has been reviewed under the provisions of VBBL 2019. 2. The Roof Deck is excluded from this application and shall not be used by patrons of the neighbourhood public house on the ground floor. 3. The time limitation on DP-2025-00909 shall be observed. ISSUED: Oct. 30, 2026 (S.Yoo) · NDY Contracting Ltd2026-10-30
#1150 - 11th floor Interior alterations to provide improvements to this existing general office on the 11th floor (#1150) of this existing commercial building on site. Scope of work: Install new kitchenette, countertop and cabinet, electriclal, plumbing and sprinkler work to suit. Building Sprinklered – Separate sprinkler permit required for proposed sprinkler work. Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). · Central West Project Management Inc.2026-10-30