This page shows what the city's open data records for one address: the zoning and what it means, the neighbourhood, every building permit on file and, where the city publishes it, the assessed value. It also shows the property on the city's aerial photo or a drawn plan, a 2021 Census profile of the small area around it, and recent permits nearby. Free, no account. Owner names and sold prices are never shown; the assessed value is the city's estimate for property tax, not a sale price.
How to use it
- Read the top lines for the summary: zoning, neighbourhood, number of permits and assessed value.
- Use + and − on the plan to zoom in and out.
- Scroll to Permit history for every permit on the lot: what was done, when, by which company, the value and the status.
- Click a nearby permit to open its address, or This week's permit digest → for the whole city.
- Something looks wrong? Use the Tell us link at the bottom and we'll check it against the city's records.
950 W Broadway, Vancouver
An address in Fairview, Vancouver, zoned C-3A (Commercial). 6 building permits are on file, most recently “#104A Interior alterations and a change of use from Office to Photography Studio to provi…” (issued 3 March 2025). The City's 2026 assessed value is $29,519,500.
Neighbourhood profile
From the 2021 Census, for the small area around this address that Statistics Canada calls a dissemination area (59150649, 663 people). Statistics Canada draws these areas; they are not the City's neighbourhoods.
Permit history
-
2025-03-03
#104A Interior alterations and a change of use from Office to Photography Studio to provide improvements for a new tenant at #104A on the ground floor of this commercial building on this site. OK for Field Review per City staff · $16,000
BOVO Development Ltd. Issued -
2024-11-19
Unit #108 Interior alterations to change the use from General Office to Fitness Centre (low occupant A2 - group D) in this unit #108 on the ground floor of this existing commercial building on this site. Ok for field review as per City staff · $2,000
no contractor listed Issued -
2023-06-21
#102 Interior alteration to change the use from General Office to Cannabis Store in this unit #102 on the main floor of this existing commercial space on this site. Scope of work includes interior wall changes. New Tenant: Team Cannabis Related to DP-2022-00572 which is time limited for a period expiring February 14, 2024. Ok for field review per City staff: - This building is sprinklered. DBI to determine on site if a separate sprinkler permit is required. - DBI to determine on site if a seismic letter is required for racking/shelving over 6ft high. - A separate sign permit is required. Energy checklist is currently no longer required with your Building Permit application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant's responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage. · $25,000
no contractor listed Issued -
2022-03-11
Suite #107 - 1st Floor Change of use from Retail Store to Fitness Centre - Class 1 and interior alterations to provide improvements for Fitness Centre tenant (Major Occupancy Group D) in unit #107 in this existing commercial building. Scope of work includes capping off existing laundry tub. The number of persons in the suite should not exceed 30 at all times. OK for field review as per City staff: 1. No Development Permit (DP) is required for change of use as Fitness Centre is outright use in C-3A and no parking changes in Central Broadway as per City staff. Processed through CRC. · $1,000
no contractor listed Issued -
2017-09-19
(#106 - ground) Interior alterations to provide improvements for new Retail Ltd foods tenant in unit #106 in this existing commercial building. OK for field review as per City staff: A/B (Arch) by Douglas Cheung, [contact removed] · $100,000
Shengren Construction Ltd Issued -
2017-07-19
Interior and exterior alterations with new kitchen exhaust including exhaust for the hot pot for this existing restaurant. Kitchen System Notes: 1. Class 1 cooking operations (Grease-Laden Vapours). 2. Commercial kitchen exhaust system to NFPA 96 (Type 1 hood), Two (2) new roof top exhaust fans and make up air units. *Separate permits are required for signs. Total occupant load for this restaurant is 96 per City staff · $600,000
no contractor listed Issued
The City of Vancouver publishes permits when they are issued and does not show whether the work was completed, so every Vancouver permit shows as Issued with its issue date.
Email alerts and sign-up aren't available yet. Everything on these pages is free to use without an account. Questions: [email protected]
Recent permits in Fairview
Interior alterations to install turnstiles in this existing Fitness Center #299 on the 2nd floor of this existing Municipally Designated Heritage commercial building. Notes: 1. With the addition of new vestibule walls, make sure they do not impact any existing sprinkler heads. If any sprinkler existing heads are to be relocated, a special sprinkler inspection is required. 2. Permit reviewed and approved to VBBL #14343 (2025). · no contractor listed2026-10-30
401 - 1750 W 2ND AV Exterior and Interior alteration to provide residential improvements including the removal of existing patio covers and increasing the size patio on the fourth floor, at unit 401 - 1750 W 2ND AV at this multiple dwelling building on the site. Ok for new guard patio per City staff. Submission under VBBL 2025 · no contractor listed2026-10-30
#320 - 3rd Floor Interior alterations to provide improvements to this new office tenant on the 3rd floor (#320) of this existing commercial building on site. Scope of work: Construct 2 new private offices, new mllwork, kitchenette, electrical and plumbing work to suit. TENANT: BC Family Doctors Building Sprinklered – Building inspector to determine on site if a separate sprinkler permit is required. Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). · Fusion Project Management Ltd2026-10-30