This page shows what the city's open data records for one address: the zoning and what it means, the neighbourhood, every building permit on file and, where the city publishes it, the assessed value. It also shows the property on the city's aerial photo or a drawn plan, a 2021 Census profile of the small area around it, and recent permits nearby. Free, no account. Owner names and sold prices are never shown; the assessed value is the city's estimate for property tax, not a sale price.
How to use it
- Read the top lines for the summary: zoning, neighbourhood, number of permits and assessed value.
- Use + and − on the plan to zoom in and out.
- Scroll to Permit history for every permit on the lot: what was done, when, by which company, the value and the status.
- Click a nearby permit to open its address, or This week's permit digest → for the whole city.
- Something looks wrong? Use the Tell us link at the bottom and we'll check it against the city's records.
3595 Kingsway, Vancouver
An address in Renfrew-Collingwood, Vancouver, zoned CD-1 (60) (Comprehensive Development). 10 building permits are on file, most recently “3593 Kingsway Interior alterations to provide first tenant improvements and a change of u…” (issued 25 September 2026). The City's 2026 assessed value for the 8 accounts at this address is $58,760,400.
Neighbourhood profile
From the 2021 Census, for the small area around this address that Statistics Canada calls a dissemination area (59153831, 755 people). Statistics Canada draws these areas; they are not the City's neighbourhoods.
Permit history
-
2026-09-25
3593 Kingsway Interior alterations to provide first tenant improvements and a change of use from Retail - Shell (Group E) for a new Beauty and Wellness Centre tenant (Group D) (approx. 1065 sq ft.) at 3593 Kingsway on the 1st level of this mixed-use building on this site. Okay for FR as per City staff · $150,000
Cypher Developments Ltd Issued -
2022-05-19
Interior alterations to provide tenant improvements to this new tenant and a change of use to retail to beauty salon Scope of work: Cosmetic work , plumbing and electrical work Ok for field review as per City staff · $50,000
no contractor listed Issued -
2021-11-02
Interior alterations to provide the first tenant improvements and change of use approx. 1,260 sq. ft. on the 1st Level (3587 Kingsway) from Retail (E) SHELL to Health Care office (D), Medical Clinic, in this existing 8 storey (7 & basement as per zoning bylaw) mixed-use building on this site. Scope of work includes: New walls to create exam rooms, kitchen/office, 2 washrooms, reception and waiting area; new plumbing and plumbing fixtures; New HVAC distribution, electrical, lighting and paint throughout. Okay to change the use from Retail Shell to health care office as per City staff: Jin Xing Song [contact removed]) DBI to determine if Sprinkler Permit is required/Required per City staff: First TI Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant’s responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage. OK for Field Review per City staff · $150,000
no contractor listed Issued -
2021-07-30
Interior alterations to change of use from retail to Health Care Office in this unit 3585 Kingsway on the ground floor of this existing mixed-use building on this site. · $300,000
no contractor listed Issued -
2021-05-21
Interior alterations to move 2 bicycle spaces from bike storage room on level 1 to the P2 level and build new 2 piece wheel ramp accessible washroom for service use only in the bike storage room on level 1 in this existing 8 storey mixed use building on this site. Scope of work includes: alterations to remove and relocate 2 bike racks to the P2 level; install new washroom - walls and door with automatic opener, wheel ramp, plumbing, HVAC fan and heater, electrical, lighting and finishes. Revision #1 issued June 11, 2021 (R. Foster) to remove "accessible washroom" from the scope of work includes information. OK for Field Review per City staff: ~ Energy Upgrade: E2 - Lighting - Upgrade to Local Control (per City staff.4.1.1.(a) of ASHRAE 90.1-2016) ~ Building Sprinklered – Building inspector to determine on site if a separate sprinkler permit is required. · $10,000
Scott Special Projects Ltd Issued -
2021-05-20
Ground floor - 3581 Kingsway Interior alterations to provide a first tenant improvements to this existing retail shell space for a new retail food tenant. Separate permit is required for the outdoor patio. OK for Field Review per City staff · $70,000
no contractor listed Issued -
2021-04-22
Interior alterations to provide the first tenant improvements to change approx. 1,099 sq. ft. on the 1st Level (3589 Kingsway) from Retail (E) SHELL to Health Care office (D) in this existing 8 storey (7 & basement as per zoning bylaw) mixed-use building on this site. Scope of work includes: New walls to create exam rooms, kitchen/office, bathroom, gym area, reception and storage; new plumbing and plumbing fixtures; New HVAC distribution, electrical, lighting and paint throughout. Tenant: Thomas Wan Physiotherapist Corporation OK for DB per City staff W.Wong, February 26, 2021 Notes: ~ Energy Upgrade: First TI ~ Building Sprinklered – a separate sprinkler permit is required. ~ Storefront glazing is to remain clear and unobstructed. No translucent or opaque film, artwork, shelving, display case, curtains or similar elements are to be installed on or directly outside or inside of the approved glazing. Separate permit is required for all signage. · $90,000
no contractor listed Issued -
2021-03-29
The change the use and major occupancy from Retail Store (shell, group E) to Restaurant-Class 1 (group A2) and to alter the interior to provide first tenant improvements in this existing mixed use building (First TI). Refer to AL-2016-00930. Class-1 cooking operation OK for DB as per City staff. · $150,000
Credton Construction Ltd Issued -
2017-12-07
To demolish this existing multiple dwelling residential rental building. · $140,000
3R Demolition Corp Issued -
2017-10-06
Interior alterations to allow salvage of non-structural building components prior to or during abatement work and removal of non-structural hazardous materials in this existing multiple dwelling building.
3R Demolition Corp Issued
The City of Vancouver publishes permits when they are issued and does not show whether the work was completed, so every Vancouver permit shows as Issued with its issue date.
Email alerts and sign-up aren't available yet. Everything on these pages is free to use without an account. Questions: [email protected]
Recent permits in Renfrew-Collingwood
#600 & # 700 - 2889 E 12TH AV Interior alteration to this existing Office (Group D) to office at #600 + 700 - 2889 E 12th Ave. on the sixth and seventh floor of this existing commercial building on this site. Ok for BP, field review per City staff · Fusion Project Management Ltd2026-11-02
To construct a Multiple Dwelling 'Multiplex' with a two-storey plus basement two dwelling unit front building and a two-storey two dwelling unit rear building with an attached 3-car carport and 1 surface parking, providing total 4 parking spaces, having vehicular access from the rear lane. Building 1: BP-2026-00771 (Site permit and Building 1 permit) - Two dwelling units (South - Front) Building 2: BP-2026-00772 - Two dwelling units (North - Rear) This permit is for site project work and construction of Building 1. Note: The entire building to be sprinklered to 2 x NFPA 13D. Note: This is a 2 storey building pursuant to the Zoning and Development By-Law 1.\tHRV proposed – Located in basement floor mechanical room 2.\tHeat Pump proposed – Exterior component located in front and east side, Interior component located in second floor closet · MINHAS HOLDINGS INC2026-10-30
*Part 5* To construct a three-storey 4-unit Multiple Dwelling "Multiplex" and detached carport with 4 parking spaces having access from the lane. Notes: 1. Building to be sprinklered to Modified NFPA 13R per bulletin 2025-003-BU 2. Schedules submitted: A / B (Struct), B (Guards), B/D (Env), B (Geo) Permit issued pursuant to VBBL 2019 · JRXL Developments Ltd2026-10-30