Permit GopherAlberta and B.C. property, permit and zoning records

2412 Alder St, Vancouver

An address in Fairview, Vancouver, zoned C-3A (Commercial). 4 building permits are on file, most recently “#212 Interior alterations to provide improvements to this existing unit #212 in this mult…” (issued 6 July 2023). The City's 2026 assessed value for the 20 accounts at this address is $16,067,821.

Zoning
C-3A · Commercial
Neighbourhood
Fairview
Permits on file
4
Assessed value (2026)
$16,067,821
20 accounts, total
Owner names are not part of the City's open data and are never shown. Sold prices are not municipal open data and are not shown. Assessed value is the City's estimate for property tax, not a sale price.
Plan of the block around 2412 Alder St, drawn from City open data, with the address marked
Parcel outlines, street centrelines and address points from the City of Vancouver's open data, drawn by Permit Gopher; not an official plan. Contains information licensed under the Open Government Licence – Vancouver.

Neighbourhood profile

From the 2021 Census, for the small area around this address that Statistics Canada calls a dissemination area (59153133, 666 people). Statistics Canada draws these areas; they are not the City's neighbourhoods.

People
666
Households
385
Median age
41.6
Median household income (2020)
$90,000
Own their home
54%
Vancouver: 45%
Average household size
1.7
Under 15
8%
65 and over
16%
Income in the 2021 Census is for the year 2020. Statistics Canada rounds counts and does not publish some figures for very small areas.

Permit history

  1. 2023-07-06 #212 Interior alterations to provide improvements to this existing unit #212 in this multiple dwelling building on the site. Scope of work is to remove a non load-bearing interior wall and kitchen upgrades only. OK for DTI as per City staff · $18,000
    Nadi Group Contracting Ltd
    Issued
  2. 2022-03-15 #105 - 1st storey Interior alterations to provide improvement to this existing unit #105 (1st storey) in this multiple dwelling building on this site. Scope of work: replace bathtub with walk in shower, install new bathroom vanity, ceiling, new pot lights, electrical and plumbing related work. OK for Field Review per City stafffficient lighting fixtures (single occupied space area)\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant’s responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage. · $14,900
    no contractor listed
    Issued
  3. 2020-12-03 Interior alterations to this existing unit #103 in this this multiple dwelling building on this site. Scope of work to remove a non-load-bearing wall in the kitchen to expand the kitchen, create a new island, replace ceiling drywall, replace ceiling insulation, new lighting in kitchen and work related to plumbing and electrical. OK For Field Review per City staff.2020 Notes: 1. DBI to determine if structural is required. Pending exposed framing review per City staff. Energy upgrade trigger: L2 - Appliances - Upgrade to an Energuide/Energy Star appliance (fridge; dishwasher) · $17,570
    no contractor listed
    Issued
  4. 2020-02-03 #318 - 3rd storey & mezzanine Interior alterations (bathroom upgrade) to the dwelling unit on the 3rd storey and mezzanine (#318) in this existing Multiple Dwelling/Health Care office Building. Scope of work on 3rd Level only and includes: to replace bathtub with a shower, new toilet and sink, add three (3) new pot lights, fire retardant barrier around drain, new double 5/8" drywall and insulation in bathroom. OK for field review as per City staff. Notes: 2 Level (3rd storey and Mezzanine) dwelling unit, no work to the mezzanine level - mezzanine plan not submitted. Energy Upgrade: L2 - SWH - Install low flow shower heads in all showers Building is not Sprinklered Related to EP-2020-00138. · $6,000
    no contractor listed
    Issued

The City of Vancouver publishes permits when they are issued and does not show whether the work was completed, so every Vancouver permit shows as Issued with its issue date.

Email alerts and sign-up aren't available yet. Everything on these pages is free to use without an account. Questions: [email protected]

Recent permits in Fairview

555 W 12TH Av
Interior alterations to install turnstiles in this existing Fitness Center #299 on the 2nd floor of this existing Municipally Designated Heritage commercial building. Notes: 1. With the addition of new vestibule walls, make sure they do not impact any existing sprinkler heads. If any sprinkler existing heads are to be relocated, a special sprinkler inspection is required. 2. Permit reviewed and approved to VBBL #14343 (2025). · no contractor listed
2026-10-30
1750 W 2ND Av
401 - 1750 W 2ND AV Exterior and Interior alteration to provide residential improvements including the removal of existing patio covers and increasing the size patio on the fourth floor, at unit 401 - 1750 W 2ND AV at this multiple dwelling building on the site. Ok for new guard patio per City staff. Submission under VBBL 2025 · no contractor listed
2026-10-30
1665 W Broadway
#320 - 3rd Floor Interior alterations to provide improvements to this new office tenant on the 3rd floor (#320) of this existing commercial building on site. Scope of work: Construct 2 new private offices, new mllwork, kitchenette, electrical and plumbing work to suit. TENANT: BC Family Doctors Building Sprinklered – Building inspector to determine on site if a separate sprinkler permit is required. Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). · Fusion Project Management Ltd
2026-10-30
Something wrong on this page? Tell us and we'll check it against the City's records.